Technical Data Sheet of NB SiC Tiles for WtE
HGSC-75A22
Item |
Unit |
Typical Values |
Guarantee values |
Test Method |
SiC |
% |
77 |
≥75 |
GB/T 16555-2008
(ISO 21068) |
Si3N4+Si2N2O |
% |
18 |
≥15 |
Others |
% |
4 |
3~5 |
Maximum application temperature
Depending on atmosphere and application |
℃ |
|
1150~1550 |
|
Bulk Density |
g/cm3 |
2.70 |
≥2.68 |
GB/T 2997-2000(ISO 5017) |
Apparent Porosity |
% |
13 |
≤15 |
GB/T 2997-2000(ISO 5017) |
Cold Crushing Strength at Room
Temperature |
MPa |
160 |
≥150 |
GB/T 5072-2008(ISO 10059) |
Cold Modulus of Rupture at Room
Temperature |
MPa |
40 |
≥35 |
GB/T 5072-2008(ISO 10059) |
Thermal expansion Coefficient at 48~1000℃ |
1/℃ |
2.8×10-6 |
≤4.5×10-6
|
GB/T 7320-2008(DIN 51045) |
Thermal Conductivity at 900℃ |
W.m-1.K-1 |
17.3 |
≥15 |
GB/T 22588-2008(DIN 51036) |
Steam Oxidation Resistance at 900℃ for
500 hours |
Volume change % |
0.5 |
≤0.6 |
ASTM C863 |
Note: 1.This product is made by a special firing
process;
2.All the values achieved by test
using the samples with specified size, which taken
from a standard brick according to GB( National
Standards) for refractory dense shaped bricks.
HGSC-75B25
Item |
Unit |
Typical Values |
Guarantee values |
Test Method |
SiC |
% |
77 |
≥75 |
GB/T 16555-2008
(ISO 21068) |
Si3N4+Si2N2O |
% |
18 |
≥15 |
Others |
% |
4 |
3~5 |
Maximum application temperature
Depending on atmosphere and application |
℃ |
|
1150~1550 |
|
Bulk Density |
g/cm3 |
2.70 |
≥2.65 |
GB/T 2997-2000
(ISO 5017) |
Apparent Porosity |
% |
14 |
≤16 |
GB/T 2997-2000
(ISO 5017) |
Cold Crushing Strength at Room
Temperature |
MPa |
150 |
≥140 |
GB/T 5072-2008
(ISO 10059) |
Cold Modulus of Rupture at Room
Temperature |
MPa |
40 |
≥35 |
GB/T 5072-2008
(ISO 10059) |
Thermal expansion Coefficient at 48~1000℃ |
1/℃ |
3.5×10-6 |
≤4.5×10-6
|
GB/T 7320-2008
(DIN 51045) |
Thermal Conductivity at 900℃ |
W.m-1.K-1 |
17.3 |
≥15 |
GB/T 22588-2008
(DIN 51036) |
Steam Oxidation Resistance at 900℃ for
500 hours |
Volume change % |
0.8 |
≤1.0 |
ASTM C863 |
Note:1) All the values achieved by test using the
samples with specified size,
which taken from a
standard brick according to GB (National Standards)
for
refractory dense shaped bricks, so, which are
subject to normal variation on
individual test.
2)The data can be adjusted according to customer’s