C
hina office Add: Unit 1416 Bld C,Jinyuan Plaza, Taiyuan Rd,Luoyang 471003, China
Tel:+86-379-64390591
cell phone:+86-13803883824
USA office:  Eric Lin (Mr)

Hans MFG
630-754-8400 (O)
Add:  1793 Commerce Dr, Montgomery, IL 60538, USA

  

         products

  

 

      Technical Data Sheet of NB SiC Tiles for WtE 

HGSC-75A22

Item  

Unit

Typical Values

Guarantee values

Test Method

SiC

%

77

≥75

GB/T 16555-2008

(ISO 21068)

Si3N4+Si2N2O

%

18

≥15

Others

%

4

3~5

Maximum application temperature Depending on atmosphere and application

℃

 

1150~1550

 

Bulk Density

g/cm3

2.70

≥2.68

GB/T 2997-2000(ISO 5017)

Apparent Porosity

%

13

≤15

GB/T 2997-2000(ISO 5017)

Cold Crushing Strength at Room Temperature

MPa

160

≥150

GB/T 5072-2008(ISO 10059)

Cold Modulus of Rupture at Room Temperature

MPa

40

≥35

GB/T 5072-2008(ISO 10059)

Thermal expansion Coefficient at 48~1000℃

1/℃

2.8×10-6

≤4.5×10-6

GB/T 7320-2008(DIN 51045)

Thermal Conductivity at 900℃

 W.m-1.K-1

17.3

≥15

GB/T 22588-2008(DIN 51036)

 Steam Oxidation Resistance at 900℃ for 500 hours

Volume change %

0.5

≤0.6

ASTM C863

 Note: 1.This product is made by a special firing process;
        2.All the values achieved by test using the samples with specified size, which taken from a standard brick according to GB( National Standards) for refractory dense shaped bricks.



        HGSC-75B25

Item  

Unit

Typical Values

Guarantee values

Test Method

SiC

%

77

≥75

GB/T 16555-2008

(ISO 21068)

Si3N4+Si2N2O

%

18

≥15

Others

%

4

3~5

Maximum application temperature
Depending on atmosphere and application

℃

 

1150~1550

 

Bulk Density

g/cm3

2.70

≥2.65

GB/T 2997-2000
(ISO 5017)

Apparent Porosity

%

14

≤16

GB/T 2997-2000
(ISO 5017)

Cold Crushing Strength at Room Temperature

MPa

150

≥140

GB/T 5072-2008
(ISO 10059)

Cold Modulus of Rupture at Room Temperature

MPa

40

≥35

GB/T 5072-2008
(ISO 10059)

Thermal expansion Coefficient at 48~1000℃

1/℃

3.5×10-6

≤4.5×10-6

GB/T 7320-2008
(DIN 51045)

Thermal Conductivity at 900℃

 W.m-1.K-1

17.3

≥15

GB/T 22588-2008
(DIN 51036)

 Steam Oxidation Resistance at 900℃ for 500 hours

Volume change %

0.8

≤1.0

ASTM C863

Note:1) All the values achieved by test using the samples with specified size,
 which taken from a standard brick according to GB (National Standards) for
refractory dense shaped bricks, so, which are subject to normal variation on
individual test.
2)The data can be adjusted according to customer
’s requirement.

Dongfang Refsource International. All rights reserved